Mon - Sun 6:00am - 6:00pmtech@towersealants.com866-897-7568

AU-1 LAB – Liquid Applied Barrier

AU-1 LAB is an elastomeric liquid WRB and flashing membrane. Spray, brush, or roll. No primer, low VOC, breathable waterproof seal. AAMA 714-22 / 714-19 compliant. Compatible with green concrete.

AU-1 LAB is a high performance, single component, Styrene Butadiene Resin (SBR) elastomeric liquid weather resistive barrier and flashing membrane. This weather resistant barrier (WRB) functions as both a membrane and flashing and is designed to protect structures from moisture intrusion, air leakage, and environmental stressors. This low-odor, waterproofing barrier can be sprayed, brushed, or rolled, and requires no primer. It is formulated to provide a permanent, breathable waterproof seal with excellent adhesion to most common substrates, including green concrete. It is low VOC, easy to apply, and is easy to clean with soap & water. AU-1 LAB can be used on rough openings, around penetrations and on broad wall applications as a weather-resistive barrier.

  • 1:
    Tested in accordance with performance requirements of ABAA for weather-resistive barrier materials
  • 2:
    Meets the performance requirements of AAMA 714-22 & 714-19
  • 3:
    Provides a breathable, waterproof seal
  • 4:
    No isocyanates or phthalates
  • 5:
    UV, mildew and weather resistant once cured
  • 6:
    Soap & water cleanup
  • 7:
    Resistant to tearing
  • 8:
    May be exposed to weather for up to 9 months without degrading performance characteristics
  • 9:
    Outstanding adhesion
  • 10:
    Paintable
  • 11:
    Can be applied to green concrete
  • 12:
    Apply by brush, sprayer, or roller
  • 13:
    18-month shelf life
  • Masonry
  • Aluminum
  • Wood
  • Concrete
  • Brick
  • Vinyl
  • Exterior Gypsum
  • Building Envelope Systems
  • OSB/Plywood Sheathing
  • Stucco

Surfaces to be free of all dirt, dust, oil, mildew, frost or other contaminants. Any structural damage must be repaired prior to application. Any non-structural cracks or joints up to ½” should be sealed with AU-1 Elastomeric Construction Sealant prior to AU-1 LAB Application. Protect property and surface not to be applied with membrane.

Use a brush, sprayer, or roller to apply AU-1 LAB to a minimum of 30 wet mils over the desired area of the rough opening including the exterior surface. Application should be done in a manner resulting in the membrane surface being free of openings or pinholes. AU-1 LAB may be applied up to 60 wet mils without sagging if required, due to substrate porosity. Backrolling is recommended after spray application. Allow product to skin before installing any components onto cladding or rough openings. Skin times may vary by humidity and conditions. Check local building codes for additional recommendations or requirements.

 

NOT INTENDED FOR AREAS THAT WILL BE SUBMERGED IN WATER. KEEP FROM FREEZING. NOT FOR FOOD CONTACT SURFACES. PRODUCT CANNOT BE SANDED.

Immediately after use, clean uncured material and tools with soap and water. Remove cured membrane by cutting with a sharp-edged tool.

  • Vehicle: 100% Styrene Butadiene Resin
  • VOC: Non-chemically curing membrane. VOC (less water and exempt compounds) <50 g/L (SCAQMD)
  • Pigment: Calcium Carbonate
  • Weights Solids: Approximately 66.42%
  • Volume Solids: Approximately 53.0%
  • Weight per Gallon: 11.11 ± 0.5
  • Specific Gravity: Approximately 1.33
  • Service Temp: -30ºF to 180ºF
  • Temp Application Range: 40ºF and rising. Air temp no hotter than 95ºF and substrate not hotter than 160ºF
  • Freeze Thaw Stability: Passes 5 Cycles@ 0ºF (1 cycle = 16hrs. @ 0ºF, 8hrs at 75ºF)
  • Flash Point: N. A.
  • Consistency: Paste / brush-able
  • Applications: Interior / Exterior
  • Life Expectancy: 60-year performance
  • Shelf Life: 18 months when stored at 50ºF to 80ºF

Product resources

AU-1 LAB – Liquid Applied Barrier resources

How AU-1 LAB Compares to Henry, Prosoco, Tremco, DOW, SIKA, PolyGuard & Traditional House Wrap

AU-1 LAB liquid-applied barrier comparison vs. Henry Air-Bloc All Weather STPE, Prosoco R-Guard Spray Wrap MVP, Tremco ExoAir 230, DOW Defendair 200C, SIKA SIKAGUARD AWB 660, PolyGuard BB LW, and traditional house wrap
AU-1 LAB Tower sealants
AU-1 LAB
Henry – Air-Bloc All Weather STPE Prosoco R-Guard Spray Wrap MVP Tremco – ExoAir 230 DOW – Defendair 200C SIKA – SIKAGUARD AWB 660 PolyGuard – BB LW Traditional House Wrap
Yes No No No No No No No
Shelf Life 18 Months12 Months24 Months12 Months12 Months2 Years Not ListedN/A
Perm Rating (E-96 water method) 1616251229141510 – 29
Air Permeance (L / s·m² at 75 Pa) 0.00080.00500.00240.0130.01170.0049 Not Listed0.004 – 0.01
SAG Resistance (max. wet mils) 6040Not ListedNot Listed42 Not ListedNot ListedN/A
Wet Mils Required* 30201048 – 7030 (2–3 Coats)2020 N/A
% Solids (volume) 53%98%63 – 68%53%51%74%90% N/A
Soap & Water Cleanup N/A
Rain Ready Time 6 – 8 hours30 minutes12 hours16 – 24 hours8 hours 2 – 10 hoursNot ListedN/A
UV Exposure Time 6 Months12 Months12 Months12 MonthsNo Limit6 Months 6 Months3 – 12 Months
Heavy-Duty Sprayer Not Required N/A
VOC (g / l) <50<25<18<18<5Not Listed <20N/A
Cure Type EvaporativeMoistureEvaporativeEvaporativeEvaporative MoistureNot ListedN/A
Coverage (sq. ft. / GL)* 50 – 10060 – 7550 – 10033Not Listed 5350 – 80N/A
Application Temp (°F) 40 – 9510 – 12225 – 10040 and Up20 – 100 25 and UpNot ListedN/A
Self-Sealing Not Listed
Tear-Resistant
Prep Not Required on <1/4" Joint

*substrate porosity dependent

AU-1 LAB Frequently Asked Questions

Does AU-1 LAB require a primer?

No. AU-1 LAB bonds directly to concrete (including green concrete), masonry, wood, OSB, aluminum, vinyl, and most common substrates without a primer.

How is AU-1 LAB applied?

By brush, roller, or sprayer, in one coat. Apply a minimum of 30 wet mils over the area, up to 60 wet mils without sagging if needed. Backrolling is recommended after spray application.

How long until it's rain-ready, and how long until it's fully cured?

AU-1 LAB is rain-ready in about 90 minutes and reaches full cure in 24–72 hours, depending on conditions.

What's the coverage rate?

About 50 square feet per gallon at 30 wet mils. It's available in 1-gallon and 5-gallon containers.

Can AU-1 LAB be applied to green (uncured) concrete?

Yes. AU-1 LAB is listed as suitable for application to green concrete, along with masonry, wood, OSB/plywood sheathing, aluminum, vinyl, brick, stucco, and exterior gypsum.

What temperature range can AU-1 LAB be applied in?

Apply when air and substrate temperatures are 40°F and rising, with air no hotter than 95°F and substrate no hotter than 160°F. Once cured, it holds up across a -30°F to 180°F service temperature range.

Is AU-1 LAB breathable, and does it seal around fasteners?

Yes to both. It provides a permanent, breathable waterproof seal (16 perms vapor permeance) and self-seals around fasteners and penetrations.

Technical Data Sheet

AU-1 LAB

Liquid-Applied Air, Water, and Flashing Barrier

Description

AU-1 LAB is a high performance, single component, Styrene Butadiene Resin (SBR) elastomeric liquid weather resistive barrier and flashing membrane. This weather resistant barrier (WRB) functions as both a membrane and flashing and is designed to protect structures from moisture intrusion, air leakage, and environmental stressors. This low-odor, waterproofing barrier can be sprayed, brushed, or rolled, and requires no primer. It is formulated to provide a permanent, breathable waterproof seal with excellent adhesion to most common substrates, including green concrete. It is low VOC, easy to apply, and is easy to clean with soap & water. AU-1 LAB can be used on rough openings, around penetrations and on broad wall applications as a weather-resistive barrier.

Performance Features

  • Tested in accordance with performance requirements of ABAA for weather-resistive barrier materials
  • Meets the performance requirements of AAMA 714-22 & 714-19
  • Provides a breathable, waterproof seal
  • No isocyanates or phthalates
  • UV, mildew and weather resistant once cured
  • Resistant to tearing
  • May be exposed to weather for up to 9 months without degrading performance characteristics
  • Outstanding adhesion
  • Paintable
  • Can be applied to green concrete
  • Apply by brush, sprayer, or roller
  • Soap & water cleanup
  • 18-month shelf life

Product Specifications

Vehicle
100% Styrene Butadiene Resin
VOC
Non-chemically curing membrane. <50 g/L less water and exempt compounds (SCAQMD)
Pigment
Calcium Carbonate
Weight / Volume Solids
~66.42% by weight · ~53.0% by volume
Weight per Gallon
11.11 ± 0.5
Specific Gravity
Approximately 1.33
Service Temp
-30°F to 180°F
Application Temp Range
40°F and rising. Air no hotter than 95°F, substrate no hotter than 160°F
Freeze-Thaw Stability
Passes 5 cycles @ 0°F (1 cycle = 16 hrs @ 0°F, 8 hrs @ 75°F)
Flash Point
N.A.
Consistency
Paste / brush-able
Applications
Interior / Exterior
Life Expectancy
60-year performance
Shelf Life
18 months when stored at 50°F to 80°F
Odor
Mild acrylic
Tooling Time
10 to 20 minutes
Tack-Free Time
60 minutes
Topcoat Time
6 to 8 hours @ 75°F and 50% humidity
Full Cure
24 to 72 hours

Packaging

5 US Gallon
Color
Blue
Item Number
TS-00462
UPC Code
843034004626
1 US Gallon
Color
Blue
Item Number
TS-00461
UPC Code
843034004619

Compatible Substrates

  • Masonry
  • Aluminum
  • Wood
  • Concrete
  • Brick
  • Vinyl
  • Exterior Gypsum
  • Building Envelope Systems
  • OSB / Plywood Sheathing
  • Stucco

Compatible Systems

Stucco, EIFS, Foamboard, Exterior Cladding Systems, Housewraps — compatible with most coatings and sealants.

Surface Preparation

Surfaces to be free of all dirt, dust, oil, mildew, frost or other contaminants. Any structural damage must be repaired prior to application. Any non-structural cracks or joints up to ½″ should be sealed with AU-1 Elastomeric Construction Sealant prior to AU-1 LAB application. Protect property and surfaces not to be applied with membrane.

Mixing

Do not induce air if product needs to be mixed. Mix at slow speeds. Do not dilute product by adding water.

Application

Use a brush, sprayer, or roller to apply AU-1 LAB to a minimum of 30 wet mils over the desired area of the rough opening, including the exterior surface. Application should be done in a manner resulting in the membrane surface being free of openings or pinholes. AU-1 LAB may be applied up to 60 wet mils without sagging if required, due to substrate porosity. Backrolling is recommended after spray application. Allow product to skin before installing any components onto cladding or rough openings — skin times may vary by humidity and conditions. Check local building codes for additional recommendations or requirements.

Not intended for areas that will be submerged in water. Keep from freezing. Not for food contact surfaces. Product cannot be sanded.

Spray Equipment

AU-1 LAB is compatible with most airless spray equipment manufacturers. Recommended tip orifice size: .021–.025. Recommended pressure: 3000 PSI. Recommended GPM: 1.15–2.5. Additional details are available in the AU-1 LAB Installation Guide.

Coverage

Approximately 50 sq ft per gallon to achieve 30 wet mils. Coverage will vary greatly depending on the porosity of the substrate and application method.

Clean-Up

Immediately after use, clean uncured material and tools with soap and water. Remove cured membrane by cutting with a sharp-edged tool.

Limitations

Only apply AU-1 LAB when product, surface, and air temperatures are above 40°F and rising. Do not apply on surfaces exceeding 160°F. Do not apply to frozen substrates, prior to extreme weather, or before heavy rain. AU-1 LAB is not for use in below-grade applications, or in areas where frequent water ponding may occur. Product can be exposed to weather and UV for up to 9 months before requiring coverage via cladding or coating. Product is not intended for use on surfaces where it will be permanently exposed.

Storage

AU-1 LAB should be stored in original, unopened containers, away from heat and direct sunlight. Product should be kept from freezing. When stored correctly, product will have a shelf life of 18 months.

Certification & Testing

ABAA Air Barrier Association of America Compliance Testing

AU-1 LAB ABAA compliance test results
PropertyValueTest Method
Water Vapor Permeance – Desiccant Method0.0000840716 (Perm, Inch-pound) / 0.0000049087 (Perm, inch)ASTM E-96
Water Vapor Permeance – Water Method0.001068777 (Perm, Inch-pound) / 0.0000445324 (Perm, inch)ASTM E-96
Average Air Permeance @ 75 Pa0.00077084 L/(Pa·m²·s) — PassASTM E2178-21a
Pull-Off Adhesion346.4 psi — PassASTM D4541
Flame Spread Index (FSI)10, Class AASTM E84
Smoke Developed Index (SDI)35, Class AASTM E84
Water ResistancePass (3 of 3, no failures)AATCC 127
Water Absorption17%ASTM D471
Sag60 milsASTM D4400-18
Crack BridgingPass (5 of 5, no failures)ASTM C1305
Nail SealabilityPass (4 of 4, no failures)ASTM D1970

AAMA 714-22: Liquid-Applied Flashing Testing

AU-1 LAB AAMA 714-22 test results
PropertyValueTest Method
Adhesive Bond to Substrates (5.1)Pass — Cement & PlywoodASTM C-794
Water Penetration Around Nails (5.2)PassAAMA 711 §5.2
Accelerated UV Aging (14 Days) Peel Adhesion (5.3)Pass (Cement)ASTM G154 Cycle 1 or G155 / C-794
Elevated Temperature Peel Adhesion (5.4)Pass (Cement & Plywood)ASTM C-794 / AAMA 711 §5.5
Thermal Cycling Peel Adhesion (5.5)Pass (Cement)AAMA 711 §5.6.3 / ASTM C-794
Crack Bridging Ability (5.6)Pass — Category 1 & 2ASTM C1305 modified per AAMA 714-19 §5.6
Water Immersion Peel Adhesion (5.7)Pass (Cement)AAMA 711 §5.8
Water Vapor Permeability (6.3)Pass — 13 permsASTM E-96

*This TDS lists water vapor permeability as 13 perms under AAMA 714-22 testing. That's different from the "16 perms" figure on the wholesale page's FAQ content — use 13 perms (the TDS number) as the source of truth and correct the wholesale page.

Safety

Irritating to skin, eyes and respiratory tract. Harmful if swallowed, inhaled or absorbed through the skin. May cause allergic skin reactions and/or central nervous system depression. Adverse reproduction effects have been reported in animals. May cause adverse kidney effects. Avoid contact with eyes, skin and clothing. Use in a well ventilated area. Wear eye, skin, and respiratory protection. Eye contact: immediately flush with water for 15 minutes and get medical attention immediately. If swallowed: do not induce vomiting; give large quantities of water and get medical attention. Never give anything by mouth to an unconscious person. For health information, refer to the Safety Data Sheet or call ChemTrec at 800-424-9300. Keep out of reach of children.

⚠ This product can expose you to chemicals, including petroleum distillates, known to the State of California to cause birth defects, reproductive harm, and/or cancer. For more information, visit www.P65Warnings.ca.gov.

Safety Data Sheets (SDS) are available upon request via towersealants.com or by calling 866-897-7568.

Warranty: Tower Sealants warrants this product to be free from manufacturing defects. The installer is responsible for testing this product on the surfaces of the targeted application for compatibility and performance prior to use. This is the sole and exclusive remedy and liability for defects or failure of this product. This warranty is in lieu of all other warranties, written or oral, statutory, expressed or implied, including without limitation any implied warranty of merchantability or fitness.

Manufacturer

Tower Sealants · 2095 Memorial Park Road, Gainesville, GA 30504
Customer Service: 866-897-7568 · Information: tech@towersealants.com · towersealants.com