AU-1 LAB – Liquid Applied Barrier
AU-1 LAB is an elastomeric liquid WRB and flashing membrane. Spray, brush, or roll. No primer, low VOC, breathable waterproof seal. AAMA 714-22 / 714-19 compliant. Compatible with green concrete.
AU-1 LAB is a high performance, single component, Styrene Butadiene Resin (SBR) elastomeric liquid weather resistive barrier and flashing membrane. This weather resistant barrier (WRB) functions as both a membrane and flashing and is designed to protect structures from moisture intrusion, air leakage, and environmental stressors. This low-odor, waterproofing barrier can be sprayed, brushed, or rolled, and requires no primer. It is formulated to provide a permanent, breathable waterproof seal with excellent adhesion to most common substrates, including green concrete. It is low VOC, easy to apply, and is easy to clean with soap & water. AU-1 LAB can be used on rough openings, around penetrations and on broad wall applications as a weather-resistive barrier.
- 1:Tested in accordance with performance requirements of ABAA for weather-resistive barrier materials
- 2:Meets the performance requirements of AAMA 714-22 & 714-19
- 3:Provides a breathable, waterproof seal
- 4:No isocyanates or phthalates
- 5:UV, mildew and weather resistant once cured
- 6:Soap & water cleanup
- 7:Resistant to tearing
- 8:May be exposed to weather for up to 9 months without degrading performance characteristics
- 9:Outstanding adhesion
- 10:Paintable
- 11:Can be applied to green concrete
- 12:Apply by brush, sprayer, or roller
- 13:18-month shelf life
- Masonry
- Aluminum
- Wood
- Concrete
- Brick
- Vinyl
- Exterior Gypsum
- Building Envelope Systems
- OSB/Plywood Sheathing
- Stucco
Surfaces to be free of all dirt, dust, oil, mildew, frost or other contaminants. Any structural damage must be repaired prior to application. Any non-structural cracks or joints up to ½” should be sealed with AU-1 Elastomeric Construction Sealant prior to AU-1 LAB Application. Protect property and surface not to be applied with membrane.
Use a brush, sprayer, or roller to apply AU-1 LAB to a minimum of 30 wet mils over the desired area of the rough opening including the exterior surface. Application should be done in a manner resulting in the membrane surface being free of openings or pinholes. AU-1 LAB may be applied up to 60 wet mils without sagging if required, due to substrate porosity. Backrolling is recommended after spray application. Allow product to skin before installing any components onto cladding or rough openings. Skin times may vary by humidity and conditions. Check local building codes for additional recommendations or requirements.
NOT INTENDED FOR AREAS THAT WILL BE SUBMERGED IN WATER. KEEP FROM FREEZING. NOT FOR FOOD CONTACT SURFACES. PRODUCT CANNOT BE SANDED.
Immediately after use, clean uncured material and tools with soap and water. Remove cured membrane by cutting with a sharp-edged tool.
- Vehicle: 100% Styrene Butadiene Resin
- VOC: Non-chemically curing membrane. VOC (less water and exempt compounds) <50 g/L (SCAQMD)
- Pigment: Calcium Carbonate
- Weights Solids: Approximately 66.42%
- Volume Solids: Approximately 53.0%
- Weight per Gallon: 11.11 ± 0.5
- Specific Gravity: Approximately 1.33
- Service Temp: -30ºF to 180ºF
- Temp Application Range: 40ºF and rising. Air temp no hotter than 95ºF and substrate not hotter than 160ºF
- Freeze Thaw Stability: Passes 5 Cycles@ 0ºF (1 cycle = 16hrs. @ 0ºF, 8hrs at 75ºF)
- Flash Point: N. A.
- Consistency: Paste / brush-able
- Applications: Interior / Exterior
- Life Expectancy: 60-year performance
- Shelf Life: 18 months when stored at 50ºF to 80ºF
Product resources
AU-1 LAB – Liquid Applied Barrier resources
How AU-1 LAB Compares to Henry, Prosoco, Tremco, DOW, SIKA, PolyGuard & Traditional House Wrap
|
Tower sealants AU-1 LAB |
Henry – Air-Bloc All Weather STPE | Prosoco R-Guard Spray Wrap MVP | Tremco – ExoAir 230 | DOW – Defendair 200C | SIKA – SIKAGUARD AWB 660 | PolyGuard – BB LW | Traditional House Wrap |
|---|---|---|---|---|---|---|---|---|
| 2-in-1 Solution WRB & Liquid-Applied Flashing |
✓Yes | ✗No | ✗No | ✗No | ✗No | ✗No | ✗No | ✗No |
| Shelf Life | 18 Months | 12 Months | 24 Months | 12 Months | 12 Months | 2 Years | Not Listed | N/A |
| Perm Rating (E-96 water method) | 16 | 16 | 25 | 12 | 29 | 14 | 15 | 10 – 29 |
| Air Permeance (L / s·m² at 75 Pa) | 0.0008 | 0.0050 | 0.0024 | 0.013 | 0.0117 | 0.0049 | Not Listed | 0.004 – 0.01 |
| SAG Resistance (max. wet mils) | 60 | 40 | Not Listed | Not Listed | 42 | Not Listed | Not Listed | N/A |
| Wet Mils Required* | 30 | 20 | 10 | 48 – 70 | 30 (2–3 Coats) | 20 | 20 | N/A |
| % Solids (volume) | 53% | 98% | 63 – 68% | 53% | 51% | 74% | 90% | N/A |
| Soap & Water Cleanup | ✓ | ✗ | ✓ | ✗ | ✓ | ✓ | ✓ | N/A |
| Rain Ready Time | 6 – 8 hours | 30 minutes | 12 hours | 16 – 24 hours | 8 hours | 2 – 10 hours | Not Listed | N/A |
| UV Exposure Time | 6 Months | 12 Months | 12 Months | 12 Months | No Limit | 6 Months | 6 Months | 3 – 12 Months |
| Heavy-Duty Sprayer Not Required | ✓ | ✗ | ✓ | ✓ | ✓ | ✓ | ✗ | N/A |
| VOC (g / l) | <50 | <25 | <18 | <18 | <5 | Not Listed | <20 | N/A |
| Cure Type | Evaporative | Moisture | Evaporative | Evaporative | Evaporative | Moisture | Not Listed | N/A |
| Coverage (sq. ft. / GL)* | 50 – 100 | 60 – 75 | 50 – 100 | 33 | Not Listed | 53 | 50 – 80 | N/A |
| Application Temp (°F) | 40 – 95 | 10 – 122 | 25 – 100 | 40 and Up | 20 – 100 | 25 and Up | Not Listed | N/A |
| Self-Sealing | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | Not Listed | ✗ |
| Tear-Resistant | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✗ |
| Prep Not Required on <1/4" Joint | ✓ | ✗ | ✗ | ✗ | ✗ | ✗ | ✗ | ✗ |
*substrate porosity dependent
AU-1 LAB Frequently Asked Questions
Does AU-1 LAB require a primer?
No. AU-1 LAB bonds directly to concrete (including green concrete), masonry, wood, OSB, aluminum, vinyl, and most common substrates without a primer.
How is AU-1 LAB applied?
By brush, roller, or sprayer, in one coat. Apply a minimum of 30 wet mils over the area, up to 60 wet mils without sagging if needed. Backrolling is recommended after spray application.
How long until it's rain-ready, and how long until it's fully cured?
AU-1 LAB is rain-ready in about 90 minutes and reaches full cure in 24–72 hours, depending on conditions.
What's the coverage rate?
About 50 square feet per gallon at 30 wet mils. It's available in 1-gallon and 5-gallon containers.
Can AU-1 LAB be applied to green (uncured) concrete?
Yes. AU-1 LAB is listed as suitable for application to green concrete, along with masonry, wood, OSB/plywood sheathing, aluminum, vinyl, brick, stucco, and exterior gypsum.
What temperature range can AU-1 LAB be applied in?
Apply when air and substrate temperatures are 40°F and rising, with air no hotter than 95°F and substrate no hotter than 160°F. Once cured, it holds up across a -30°F to 180°F service temperature range.
Is AU-1 LAB breathable, and does it seal around fasteners?
Yes to both. It provides a permanent, breathable waterproof seal (16 perms vapor permeance) and self-seals around fasteners and penetrations.
Technical Data Sheet
AU-1 LAB
Liquid-Applied Air, Water, and Flashing Barrier
Description
AU-1 LAB is a high performance, single component, Styrene Butadiene Resin (SBR) elastomeric liquid weather resistive barrier and flashing membrane. This weather resistant barrier (WRB) functions as both a membrane and flashing and is designed to protect structures from moisture intrusion, air leakage, and environmental stressors. This low-odor, waterproofing barrier can be sprayed, brushed, or rolled, and requires no primer. It is formulated to provide a permanent, breathable waterproof seal with excellent adhesion to most common substrates, including green concrete. It is low VOC, easy to apply, and is easy to clean with soap & water. AU-1 LAB can be used on rough openings, around penetrations and on broad wall applications as a weather-resistive barrier.
Performance Features
- Tested in accordance with performance requirements of ABAA for weather-resistive barrier materials
- Meets the performance requirements of AAMA 714-22 & 714-19
- Provides a breathable, waterproof seal
- No isocyanates or phthalates
- UV, mildew and weather resistant once cured
- Resistant to tearing
- May be exposed to weather for up to 9 months without degrading performance characteristics
- Outstanding adhesion
- Paintable
- Can be applied to green concrete
- Apply by brush, sprayer, or roller
- Soap & water cleanup
- 18-month shelf life
Product Specifications
- Vehicle
- 100% Styrene Butadiene Resin
- VOC
- Non-chemically curing membrane. <50 g/L less water and exempt compounds (SCAQMD)
- Pigment
- Calcium Carbonate
- Weight / Volume Solids
- ~66.42% by weight · ~53.0% by volume
- Weight per Gallon
- 11.11 ± 0.5
- Specific Gravity
- Approximately 1.33
- Service Temp
- -30°F to 180°F
- Application Temp Range
- 40°F and rising. Air no hotter than 95°F, substrate no hotter than 160°F
- Freeze-Thaw Stability
- Passes 5 cycles @ 0°F (1 cycle = 16 hrs @ 0°F, 8 hrs @ 75°F)
- Flash Point
- N.A.
- Consistency
- Paste / brush-able
- Applications
- Interior / Exterior
- Life Expectancy
- 60-year performance
- Shelf Life
- 18 months when stored at 50°F to 80°F
- Odor
- Mild acrylic
- Tooling Time
- 10 to 20 minutes
- Tack-Free Time
- 60 minutes
- Topcoat Time
- 6 to 8 hours @ 75°F and 50% humidity
- Full Cure
- 24 to 72 hours
Packaging
- Color
- Blue
- Item Number
- TS-00462
- UPC Code
- 843034004626
- Color
- Blue
- Item Number
- TS-00461
- UPC Code
- 843034004619
Compatible Substrates
- Masonry
- Aluminum
- Wood
- Concrete
- Brick
- Vinyl
- Exterior Gypsum
- Building Envelope Systems
- OSB / Plywood Sheathing
- Stucco
Compatible Systems
Stucco, EIFS, Foamboard, Exterior Cladding Systems, Housewraps — compatible with most coatings and sealants.
Surface Preparation
Surfaces to be free of all dirt, dust, oil, mildew, frost or other contaminants. Any structural damage must be repaired prior to application. Any non-structural cracks or joints up to ½″ should be sealed with AU-1 Elastomeric Construction Sealant prior to AU-1 LAB application. Protect property and surfaces not to be applied with membrane.
Mixing
Do not induce air if product needs to be mixed. Mix at slow speeds. Do not dilute product by adding water.
Application
Use a brush, sprayer, or roller to apply AU-1 LAB to a minimum of 30 wet mils over the desired area of the rough opening, including the exterior surface. Application should be done in a manner resulting in the membrane surface being free of openings or pinholes. AU-1 LAB may be applied up to 60 wet mils without sagging if required, due to substrate porosity. Backrolling is recommended after spray application. Allow product to skin before installing any components onto cladding or rough openings — skin times may vary by humidity and conditions. Check local building codes for additional recommendations or requirements.
Not intended for areas that will be submerged in water. Keep from freezing. Not for food contact surfaces. Product cannot be sanded.
Spray Equipment
AU-1 LAB is compatible with most airless spray equipment manufacturers. Recommended tip orifice size: .021–.025. Recommended pressure: 3000 PSI. Recommended GPM: 1.15–2.5. Additional details are available in the AU-1 LAB Installation Guide.
Coverage
Approximately 50 sq ft per gallon to achieve 30 wet mils. Coverage will vary greatly depending on the porosity of the substrate and application method.
Clean-Up
Immediately after use, clean uncured material and tools with soap and water. Remove cured membrane by cutting with a sharp-edged tool.
Limitations
Only apply AU-1 LAB when product, surface, and air temperatures are above 40°F and rising. Do not apply on surfaces exceeding 160°F. Do not apply to frozen substrates, prior to extreme weather, or before heavy rain. AU-1 LAB is not for use in below-grade applications, or in areas where frequent water ponding may occur. Product can be exposed to weather and UV for up to 9 months before requiring coverage via cladding or coating. Product is not intended for use on surfaces where it will be permanently exposed.
Storage
AU-1 LAB should be stored in original, unopened containers, away from heat and direct sunlight. Product should be kept from freezing. When stored correctly, product will have a shelf life of 18 months.
Certification & Testing
ABAA Air Barrier Association of America Compliance Testing
| Property | Value | Test Method |
|---|---|---|
| Water Vapor Permeance – Desiccant Method | 0.0000840716 (Perm, Inch-pound) / 0.0000049087 (Perm, inch) | ASTM E-96 |
| Water Vapor Permeance – Water Method | 0.001068777 (Perm, Inch-pound) / 0.0000445324 (Perm, inch) | ASTM E-96 |
| Average Air Permeance @ 75 Pa | 0.00077084 L/(Pa·m²·s) — Pass | ASTM E2178-21a |
| Pull-Off Adhesion | 346.4 psi — Pass | ASTM D4541 |
| Flame Spread Index (FSI) | 10, Class A | ASTM E84 |
| Smoke Developed Index (SDI) | 35, Class A | ASTM E84 |
| Water Resistance | Pass (3 of 3, no failures) | AATCC 127 |
| Water Absorption | 17% | ASTM D471 |
| Sag | 60 mils | ASTM D4400-18 |
| Crack Bridging | Pass (5 of 5, no failures) | ASTM C1305 |
| Nail Sealability | Pass (4 of 4, no failures) | ASTM D1970 |
AAMA 714-22: Liquid-Applied Flashing Testing
| Property | Value | Test Method |
|---|---|---|
| Adhesive Bond to Substrates (5.1) | Pass — Cement & Plywood | ASTM C-794 |
| Water Penetration Around Nails (5.2) | Pass | AAMA 711 §5.2 |
| Accelerated UV Aging (14 Days) Peel Adhesion (5.3) | Pass (Cement) | ASTM G154 Cycle 1 or G155 / C-794 |
| Elevated Temperature Peel Adhesion (5.4) | Pass (Cement & Plywood) | ASTM C-794 / AAMA 711 §5.5 |
| Thermal Cycling Peel Adhesion (5.5) | Pass (Cement) | AAMA 711 §5.6.3 / ASTM C-794 |
| Crack Bridging Ability (5.6) | Pass — Category 1 & 2 | ASTM C1305 modified per AAMA 714-19 §5.6 |
| Water Immersion Peel Adhesion (5.7) | Pass (Cement) | AAMA 711 §5.8 |
| Water Vapor Permeability (6.3) | Pass — 13 perms | ASTM E-96 |
*This TDS lists water vapor permeability as 13 perms under AAMA 714-22 testing. That's different from the "16 perms" figure on the wholesale page's FAQ content — use 13 perms (the TDS number) as the source of truth and correct the wholesale page.
Safety
Irritating to skin, eyes and respiratory tract. Harmful if swallowed, inhaled or absorbed through the skin. May cause allergic skin reactions and/or central nervous system depression. Adverse reproduction effects have been reported in animals. May cause adverse kidney effects. Avoid contact with eyes, skin and clothing. Use in a well ventilated area. Wear eye, skin, and respiratory protection. Eye contact: immediately flush with water for 15 minutes and get medical attention immediately. If swallowed: do not induce vomiting; give large quantities of water and get medical attention. Never give anything by mouth to an unconscious person. For health information, refer to the Safety Data Sheet or call ChemTrec at 800-424-9300. Keep out of reach of children.
⚠ This product can expose you to chemicals, including petroleum distillates, known to the State of California to cause birth defects, reproductive harm, and/or cancer. For more information, visit www.P65Warnings.ca.gov.
Safety Data Sheets (SDS) are available upon request via towersealants.com or by calling 866-897-7568.
Manufacturer
Tower Sealants · 2095 Memorial Park Road, Gainesville, GA 30504
Customer Service: 866-897-7568 · Information: tech@towersealants.com · towersealants.com