Lun - Dom 6:00 a. m. - 6:00 p. m.tech@towersealants.com866-897-7568

Ex-Cell

Ex-Cell es un sellador para construcción de uso general que ofrece buena adherencia y durabilidad en ventanas, molduras, puertas, cielorrasos, paneles de yeso y rejillas de aire acondicionado. Forma un sello flexible y resistente al agua. Cumple con la norma ASTM C-834. Garantía de 40 años.

Colores:

EX-CELL Siliconized Latex Caulk is a quality general purpose caulk. This Siliconized latex based caulk can be used on a wide variety of interior and exterior surfaces delivering good adhesion and durability. It forms a flexible, durable, airtight, water resistant seal that offers protection from environmental conditions. Once cured, the bead is mildew resistant. It is low odor, easy to apply and is soap and water cleanup.

  • 1:
    Meets ASTM C-834, Type OP, Grade 0°C.
  • 2:
    Meets ASTM E90-09 for use in acoustical applications when used as described in ASTM C919
  • 3:
    Up to 1/2” in properly designed joints
  • 4:
    Pintable
  • 5:
    Provides a flexible, durable seal
  • 6:
    All purpose
  • 7:
    Interior / Exterior
  • 8:
    Vacuum Filled Tubes
  • 9:
    40-year guarantee
  • Windows
  • Trim
  • Penetrations
  • Doors
  • Flashings
  • Counters
  • Siding
  • Albañilería
  • Ceramic Tile
  • Madera
  • Concreto
  • Glass
  • Metal
  • Ladrillo

Surfaces to be caulked must be dry and free of all dirt, dust, oil, mildew, loose paint, old caulk or other contaminates. Only apply when sealant, surface, and air temperature are above 40ºF and rising. Do not apply on surfaces that exceed 120ºF, or when rain is expected.

  1. Cut nozzle at a 45º angle. Cured bead should be between 1/8” and 1/2” wide. Use a foam backer rod for joints that exceed 1/2” in depth.
  2. Smooth bead with a moistened cloth.
  3. Clean up uncured material and tools with soap and water.
  4. Allow 4 to 6 hours before painting.

Coverage: 55 linear feet for a 3/16” bead.

NOT INTENDED FOR AREAS THAT WILL BE SUBMERGED IN WATER. KEEP FROM FREEZING. NOT FOR FOOD CONTACT SURFACES.

Immediately after use, clean uncured material and tools with soap and water. Remove cured sealant by cutting with a sharp-edged tool.

  • Vehicle: Acrylic Polymer Latex / Siliconized
  • VOC: Non-chemically curing sealant. VOC (less exempt solvents) is <1.5%
  • Pigment: Calcium Carbonate
  • Solids: Approximately 82%
  • Weight per Gallon: 13.5 ± 0.5
  • Specific Gravity: Approximately 1.62
  • Service Temp: -25ºF to 180ºF
  • Temp Application Range: 40ºF and rising. Air temp no hotter than 95º and substrate not hotter than 120º
  • Freeze Thaw Stability: Passes 5 Cycles@ 0ºF (1 cycle = 16hrs. @ 0ºF, 8hrs at 75ºF)
  • Flash Point: None
  • Consistency: 15 to 25 G/S @ 75ºF (SEMCO gun at 50psi)
  • Applications: Interior / Exterior
  • Life Expectancy: 40-year performance
  • Shelf Life: 24 months when stored at 50ºF to 80ºF
  • Coverage: 10.1 fl oz: 55 linear ft. at a 3/16” bead
  • Odor: Mild Sweet Acrylic
  • Tooling Time: 5 to 10 Minutes
  • Tack Free Time: 45 Minutes
  • Paint Over Time: 4 to 6 hours
  • Full Cure: 7-14 Days

Recursos del producto

Ex-Cell recursos

Ex-Cell Frequently Asked Questions

¿Qué hace que Ex-Cell sea adecuado para aplicaciones acústicas?

Ex-Cell cumple con la norma ASTM E90-09 para su uso en aplicaciones acústicas cuando se utiliza como se describe en la norma ASTM C919, además de cumplir con la norma ASTM C-834 (Tipo OP, Grado 0 °C) en cuanto al rendimiento general de selladores.

¿Para qué tamaño de junta está clasificado Ex-Cell?

Hasta 1/2 pulgada en juntas diseñadas adecuadamente. Use un cordón de respaldo de espuma para juntas que excedan 1/2 pulgada de profundidad.

¿Cuánto tiempo debo esperar antes de pintar sobre Ex-Cell?

Espere de 4 a 6 horas antes de pintar. El curado completo se alcanza en un plazo de 7 a 14 días.

¿A qué temperatura se puede aplicar Ex-Cell?

Aplique cuando el sellador, la superficie y la temperatura del aire estén por encima de los 40 °F y en aumento, con el aire a no más de 95 °F y el sustrato a no más de 120 °F. Una vez curado, resiste en un rango de temperatura de servicio de -25 °F a 180 °F.

What substrates does Ex-Cell work on?

Masonry, ceramic tile, wood, concrete, glass, metal, and brick.

How much coverage do I get from one tube?

A 10.1 fl oz tube covers about 55 linear feet at a 3/16 inch bead.

Can Ex-Cell be used in submerged or food-contact areas?

No. It's not intended for areas that will be submerged in water or for food contact surfaces, and it should be kept from freezing before use.

What warranty does Ex-Cell come with?

A 40-year guarantee. If the product cracks, peels, or separates within 40 years of installation after proper storage and application, Tower Sealants will replace it when the purchaser returns proof of purchase.

What's the difference between Ex-Cell and Accura TT-S?

Ex-Cell is a siliconized latex caulk positioned as a quality general-purpose sealant, backed by a 40-year guarantee, a -25°F to 180°F service range, and a 120°F substrate application limit. Accura TT-S is a 100% acrylic elastomeric Government Specification Sealant that additionally exceeds ASTM C-920 and Federal Spec TTS-00230C, carries a 60-year guarantee, and holds up to a wider -35°F to 180°F service range with a higher 140°F substrate limit. Both meet ASTM C-834 and are rated for acoustical use, but Accura TT-S is the higher-spec, longer-warranty option of the two.

Technical Data Sheet

Ex-Cell

Siliconized Latex Caulk

Description

Ex-Cell Siliconized Latex Caulk is a quality general purpose caulk. This siliconized latex-based caulk can be used on a wide variety of interior and exterior surfaces, delivering good adhesion and durability. It forms a flexible, durable, airtight, water resistant seal that offers protection from environmental conditions. Once cured, the bead is mildew resistant. It is low odor, easy to apply, and cleans up with soap and water.

Características de rendimiento

  • Meets ASTM C-834, Type OP, Grade 0°C
  • Meets ASTM E90-09 for acoustical applications per ASTM C919
  • Up to 1/2" in properly designed joints
  • Pintable
  • Provides a flexible, durable seal
  • All purpose
  • Interior / Exterior
  • Vacuum filled tubes
  • 40-year guarantee

Especificaciones del producto

Vehículo
Acrylic Polymer Latex / Siliconized
Voz
Non-chemically curing sealant. <1.5% less exempt solvents
Pigment
Calcium Carbonate
Solids
Approximately 82%
Weight per Gallon
13.5 ± 0.5
Specific Gravity
Approximately 1.62
Temporal de servicio
-25°F to 180°F
Application Temp Range
40°F and rising. Air no hotter than 95°F, substrate no hotter than 120°F
Freeze-Thaw Stability
Passes 5 cycles @ 0°F (1 cycle = 16 hrs @ 0°F, 8 hrs @ 75°F)
Flash Point
None
Consistency
15 to 25 G/S @ 75°F (SEMCO gun at 50 psi)
Aplicaciones
Interior / Exterior
Esperanza de vida
40-year performance
Vida útil
24 months when stored at 50°F to 80°F
Cobertura
10.1 fl oz: 55 linear ft. at a 3/16" bead
Odor
Mild sweet acrylic
Tooling Time
5 to 10 minutes
Tack-Free Time
45 minutes
Paint Over Time
4 to 6 hours
Curación total
7 to 14 days

Packaging

Cartridge
10.1 fl oz (299 ml)
TS-00500 · 843034005005

Color: White.

Aplicaciones

  • Windows
  • Doors
  • Counters
  • Trim
  • Flashings
  • Penetrations
  • Siding

Sustratos

  • Albañilería
  • Concreto
  • Ceramic tile
  • Glass
  • Madera
  • Metal
  • Ladrillo

Preparación de la superficie

Surfaces to be caulked must be dry and free of all dirt, dust, oil, mildew, loose paint, old caulk, or other contaminants. Only apply when sealant, surface, and air temperature are above 40°F and rising. Do not apply on surfaces that exceed 120°F, or when rain is expected.

Aplicación

  1. Cut nozzle at a 45° angle. Cured bead should be between 1/8″ and 1/2″ wide. Use a foam backer rod for joints that exceed 1/2″ in depth.
  2. Smooth bead with a moistened cloth.
  3. Clean up uncured material and tools with soap and water.
  4. Allow 4 to 6 hours before painting.

Coverage: 55 linear feet for a 3/16″ bead.

Not intended for areas that will be submerged in water. Keep from freezing. Not for food contact surfaces.

Clean-Up

Immediately after use, clean uncured material and tools with soap and water. Remove cured sealant by cutting with a sharp-edged tool.

Safety

Irritating to skin, eyes and respiratory tract. Harmful if swallowed, inhaled or absorbed through the skin. May cause allergic skin reactions and/or central nervous system depression. Adverse reproduction effects have been reported in animals. May cause adverse kidney effects. Avoid contact with eyes, skin and clothing. Use in a well ventilated area. Wear eye, skin, and respiratory protection. Eye contact: immediately flush with water for 15 minutes and get medical attention immediately. If swallowed: do not induce vomiting; give large quantities of water and get medical attention. Never give anything by mouth to an unconscious person. For health information, refer to the Safety Data Sheet or call ChemTrec at 800-424-9300. Keep out of reach of children.

⚠ Cancer and Reproductive Harm — go to www.P65Warnings.ca.gov for additional information.

First Aid

In case of skin contact, wash off quickly with plenty of soap and water and remove contaminated clothing. For eye contact, flush eyes immediately with large quantities of water for at least 15 minutes. If swallowed, obtain medical treatment immediately — do not induce vomiting. If inhalation causes physical discomfort, move to fresh air; if discomfort persists or any breathing difficulty occurs, seek medical help.

Safety Data Sheets (SDS) are available upon request via towersealants.com or by calling 866-897-7568.

Product Replacement Policy: After proper storage and application, if this product cracks, peels or separates within 40 years of installation, manufacturer will replace the product if purchaser returns proof of purchase to manufacturer. Manufacturer shall not be held liable for damages in excess of the purchase price. This is the sole and exclusive remedy and liability for defects or failure of this product. This warranty is in lieu of all other warranties, written or oral, statutory, expressed or implied, including without limitation any implied warranty of merchantability or fitness.

Fabricante

Tower Sealants, LLC · 2095 Memorial Park Road, Gainesville, GA 30504
Customer Service: 866-897-7568 · Information: tech@towersealants.com · towersealants.com

Ponerse en contacto

Ingrese sus datos y nos pondremos en contacto con usted en breve.